{"product_id":"pure-aire-tx-1100-dkf25-trace-oxygen-analyzer","title":"Pure Aire TX-1100-DKF25 Trace Oxygen Analyzer Monitoring System","description":"\n\u003cdiv style=\"width: 100%; max-width: 1100px; margin: 0 !important; text-align: left !important; font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; color: #2d3748; line-height: 1.5; padding: 0;\"\u003e\n    \u003cdiv style=\"background: linear-gradient(90deg, #1F3A55 0%, #2c5282 100%); padding: 25px; border-radius: 4px; color: #ffffff; margin-bottom: 30px; box-shadow: 0 4px 6px rgba(0,0,0,0.1);\"\u003e\n        \u003ch1 style=\"font-size: 32px; margin: 0; font-weight: 800; letter-spacing: -0.5px; text-transform: uppercase; color: #ffffff !important;\"\u003ePure Aire TX-1100-DKF25 Trace Oxygen Analyzer Monitoring System\u003c\/h1\u003e\n        \u003cp style=\"font-size: 18px; opacity: 0.9; margin: 8px 0 0 0; font-weight: 400;\"\u003eProfessional Trace Oxygen Analyzer\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003csection style=\"margin-bottom: 40px; border-left: 6px solid #1F3A55; padding-left: 20px;\"\u003e\n        \u003cp style=\"font-size: 16px; color: #4a5568; max-width: 850px;\"\u003eThe Pure Aire TX-1100-DKF25 Trace Oxygen Analyzer Monitoring System delivers precise and reliable oxygen detection for industrial and environmental applications. Engineered for high sensitivity and stability, this analyzer ensures accurate trace oxygen measurement to optimize process control and safety. Its robust design and advanced sensor technology make it ideal for continuous monitoring in demanding environments.\u003c\/p\u003e\n    \u003c\/section\u003e\n    \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 40px;\"\u003e\n        \u003cdiv style=\"flex: 1; min-width: 320px; background-color: #f8fafc; padding: 25px; border-radius: 6px; border: 1px solid #e2e8f0;\"\u003e\n            \u003ch3 style=\"font-size: 18px; color: #1F3A55; margin-top: 0; margin-bottom: 20px; font-weight: 700; display: flex; align-items: center;\"\u003e\n\u003cspan style=\"width: 4px; height: 18px; background: #1F3A55; display: inline-block; margin-right: 10px;\"\u003e\u003c\/span\u003e Technical Specifications\u003c\/h3\u003e\n            \u003cdiv style=\"font-size: 14px;\"\u003e\n                \u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eModel\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003eTX-1100-DKF25\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eBrand\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003ePure Aire\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eMeasurement Range\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003e0-25 ppm O2\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eDetection Method\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003eElectrochemical sensor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eResponse Time\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003eLess than 10 seconds\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eOperating Temperature\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003e-10°C to 50°C\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003ePower Supply\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003e110-240V AC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eOutput Signal\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003e4-20 mA analog output\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eDisplay\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003eDigital LCD readout\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eDimensions\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003e12 x 8 x 6 inches\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; justify-content:space-between; padding:10px 0; border-bottom:1px solid #e2e8f0;\"\u003e\n\u003cspan style=\"color:#718096\"\u003eWeight\u003c\/span\u003e\u003cspan style=\"font-weight:700; color:#000\"\u003e5.5 lbs\u003c\/span\u003e\n\u003c\/div\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex: 1; min-width: 320px; padding: 5px;\"\u003e\n            \u003ch3 style=\"font-size: 18px; color: #1F3A55; margin-top: 0; margin-bottom: 20px; font-weight: 700;\"\u003eKey Features\u003c\/h3\u003e\n            \u003cul style=\"padding-left: 0; list-style: none; font-size: 14px; color: #4a5568;\"\u003e\n                \u003cli style=\"margin-bottom:15px; display:flex; align-items:flex-start;\"\u003e\n\u003cspan style=\"color:#1F3A55; margin-right:10px; font-weight:bold;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eProfessional QC: 24h burn-in testing before shipment\u003c\/span\u003e\n\u003c\/li\u003e\n                \u003cli style=\"margin-bottom:15px; display:flex; align-items:flex-start;\"\u003e\n\u003cspan style=\"color:#1F3A55; margin-right:10px; font-weight:bold;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eSecure Logistics: Reinforced packaging for safety\u003c\/span\u003e\n\u003c\/li\u003e\n                \u003cli style=\"margin-bottom:15px; display:flex; align-items:flex-start;\"\u003e\n\u003cspan style=\"color:#1F3A55; margin-right:10px; font-weight:bold;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eTax\/Duty Note: EU buyers responsible for VAT \u0026amp; import duties\u003c\/span\u003e\n\u003c\/li\u003e\n                \u003cli style=\"margin-bottom:15px; display:flex; align-items:flex-start;\"\u003e\n\u003cspan style=\"color:#1F3A55; margin-right:10px; font-weight:bold;\"\u003e✔\u003c\/span\u003e\u003cspan\u003eCalibration: Certificates available on request\u003c\/span\u003e\n\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background-color: #f1f5f9; border: 2px solid #1F3A55; border-radius: 8px; padding: 30px; position: relative; overflow: hidden;\"\u003e\n        \u003cdiv style=\"position: absolute; right: 15px; bottom: 5px; font-size: 30px; font-weight: 900; color: #e2e8f0; z-index: 0; pointer-events: none;\"\u003eZYYKZ Test Equipment\u003c\/div\u003e\n        \u003cdiv style=\"position: relative; z-index: 1;\"\u003e\n            \u003ch3 style=\"font-size: 20px; color: #1F3A55; margin-top: 0; margin-bottom: 15px; font-weight: 800; text-transform: uppercase;\"\u003eContact for Inquiry\u003c\/h3\u003e\n            \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 40px; align-items: center;\"\u003e\n                \u003cdiv\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #64748b;\"\u003eSales Manager\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 22px; color: #1F3A55; font-weight: 800;\"\u003eJack\u003c\/p\u003e\n\u003c\/div\u003e\n                \u003cdiv\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #64748b;\"\u003eEmail Address\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 18px; color: #1F3A55; font-weight: 600;\"\u003ejack.zyykz@gmail.com\u003c\/p\u003e\n\u003c\/div\u003e\n                \u003cdiv\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #64748b;\"\u003eShipping Hub\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 18px; color: #1F3A55; font-weight: 600;\"\u003eShenzhen, China\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"margin-top: 25px; padding-top: 15px; border-top: 1px solid #cbd5e1; font-size: 12px; color: #64748b; line-height: 1.6;\"\u003e\u003cstrong\u003eIndustrial Compliance Notice:\u003c\/strong\u003e This TX-1100-DKF25 is classified as professional-grade \u003cstrong\u003eIndustrial Test \u0026amp; Measurement Equipment\u003c\/strong\u003e. It is engineered for laboratory, research, and manufacturing environments and is \u003cu\u003enot\u003c\/u\u003e intended for consumer or medical use.\u003c\/p\u003e\n            \u003cp style=\"margin-top: 10px; font-size: 11px; color: #94a3b8; font-style: italic;\"\u003eZYYKZ Test Equipment - Your Trusted Source for Professionally Tested Pre-owned Instruments. Specialized in High-Precision Test Solutions since 2019. Technical expertise in Agilent, Keysight, Tektronix \u0026amp; Fluke systems.\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Pure Aire","offers":[{"title":"Default Title","offer_id":42574088732734,"sku":"zyykz04772","price":2180.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/5011\/4110\/files\/s-l1600_6c7a24df-4636-48cd-ad6e-e0e3fa6716cc.webp?v=1774106589","url":"https:\/\/www.zyykz.com\/products\/pure-aire-tx-1100-dkf25-trace-oxygen-analyzer","provider":"ZYYKZ Test Equipment","version":"1.0","type":"link"}